Owner`s manual

OM-2226 Page 40
B. Setting Programmable TIG Impulse Start Amperage (All Models)
NOTE: Before accessing programmable
TIG HF Impulse Start Amperage mode, be
sure that all procedures and parameters
are established. Especially, check for prop-
er amperage setting (see Section 4-8). Pa-
rameter adjustment is limited while pro-
grammable TIG Impulse Start Amperage
mode is active.
Welding cycle can be executed while in
programmable start mode, but program pa-
rameters cannot be adjusted while in this
mode.
1 Amperage Switch Pad
2 Encoder Control
To adjust TIG HF Impulse Start Amperage
proceed as follows:
Press Amperage switch pad. Switch pad
LED turns on, meter A LED turns on, and
[SEL] [25] is displayed on meters. TIG HF Im-
pulse LED is on. Note: If a remote mode
and pulser functions are active, their re-
spective LEDs will be illuminated.
The 25 displayed on the amps meter is
DC start amps (it is also the factory default
setting), and can be adjusted from 1 to 200
amps by turning the Encoder control.
To change start time, proceed to Section C.
To save changes to TIG HF Impulse Start
Amperage without changing start time, turn
power Off.
Non CE Models Only
1
2
SEL
25