Owner`s manual

OM-2226 Page 31
1 Output Control
Press switch pad until desired parameter
LED is illuminated.
RMT 2T Hold
Press switch pad to activate function.
Torch trigger operation is as shown.
NOTE: A foot or finger remote control
must be connected to the welding power
source, only trigger input is functional.
NOTE: Amperage is controlled by the
welding power source.
NOTE: Switch function can be reconfi-
gured for 4T, 4TE, Mini Logic, or Spot con-
trol (see Section 4-14).
Application: Use Remote Trigger Hold
(2T) when long extended welds are
made. Remote Trigger Hold (2T) can help
to reduce operator fatigue.
ON
Press switch pad to activate function.
Output will be available when LED is illu-
minated.
NOTE: A remote contactor control is not
required.
Application: Use Output On for Stick
(SMAW) welding, or for Lift-Arc without
the use of a remote control.
NOTE: If torch trigger is held more than 3 seconds, operation reverts to Remote Trigger (Standard) mode. If arc is broken
and trigger is depressed, HLP-10 will be displayed (see Section 5-3).
Current (A)
Preflow
Initial Amps
Initial Slope
Final Slope
Postflow
Push & Release Trigger
In Less Than 3 Sec.
Weld Amps
Final Amps
Remote 2T Torch Trigger Operation
Push & Release Trigger.