3-13. Electrical Service Guide
Actual input voltage cannot exceed ± 10% of indicated required input voltage. If
actual input voltage is outside of this range, no output is available.
NOTE
Single-Phase,
100% Duty
Cycle
Single-Phase,
60% Duty
Cycle
Three-Phase, 60% Duty
Cycle
Input Voltage
115 230 230 400 460
Input Amperes At Rated Output 25 22 13.1 7.4 6.4
Max Recommended Standard Fuse Rating In Amperes
1
Normal Operating
2
35 30 20 10 10
Min Input Conductor Size In AWG/Kcmil 10 12 14 14 14
Max Recommended Input Conductor Length In Feet (Meters) 57 (17) 79 (24)
102
(31)
308
(94)
407
(124)
Min Grounding Conductor Size In AWG/Kcmil 10 12 14 14 14
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).