Owner`s manual
OM-2226 Page 21
3-11. Stick DCEP (Direct Current Electrode Positive) Connections
Ref. ST-802 471
Y Turn off power before mak-
ing connections.
1 Negative (–) Weld Output
Terminal
Connect work lead to negative weld
output terminal.
2 Positive (+) Weld Output
Terminal
Connect electrode holder to posi-
tive weld output terminal.
3 Remote 14 Receptacle
If desired, connect remote control
to Remote 14 receptacle (see Sec-
tion 3-6).
1
2
3