Owner`s manual

OM-2226 Page 13
SECTION 3 INSTALLATION
3-1. Specifications
Welding Max.
Amperes Input At Rated Output, 50/60Hz
Input Power Rated Output
Amperage
Range
Open-Circuit
Voltage
115 230 400 460
KVA KW
Three-Phase
Stick Process
150 A @ 26 VDC,
60% Duty Cycle
1 200
80
9-14
-
13.1
0.16*
7.4
0.24*
6.4
0.25*
5.2
0.06*
5.0
0.03*
Three-Phase
TIG Process
175 A @ 17 VDC,
60% Duty Cycle
1 200
80
9-14
-
10.5
0.16*
6.0
0.24*
5.2
0.25*
4.2
0.06*
4.0
0.03*
Three-Phase
Stick Process
200 A @ 28 VDC,
30% Duty Cycle
1 200
80
9-14
18.4
0.16*
10.3
0.24*
8.9
0.25*
7.3
0.06*
7.0
0.03*
Three-Phase
TIG Process
200 A @ 18 VDC,
40% Duty Cycle
1 200
80
9-14
12.7
0.16*
7.2
0.24*
6.2
0.25*
5.1
0.06*
4.9
0.03*
Single-Phase
Stick Process
150 A @ 26 VDC,
60% Duty Cycle
1 200
80
9-14
-
21.7
0.23*
-
10.6
.25*
5.0
0.05*
5.0
0.02*
Single-Phase
TIG Process
175 A @ 17 VDC,
60% Duty Cycle
1 200
80
9-14
-
17.4
0.23*
-
8.5
.25*
4.0
0.05*
4.0
0.02*
Single-Phase
Stick Process
125 A @ 25 VDC,
50% Duty Cycle
1 200
80
9-14
34.1
0.42*
-
- -
4.0
0.05*
3.8
0.03*
Single-Phase
TIG Process
150 A @ 16 VDC,
70% Duty Cycle
1 200
80
9-14
29.7
0.42*
-
- -
3.4
0.05*
3.4
0.03*
Single-Phase
Stick Process
100 A @ 24 VDC,
80% Duty Cycle
1 200
80
9-14
28.1
0.42*
- - -
3.2
0.05*
3.2
0.03*
Single-Phase
TIG Process
125 A @ 15 VDC,
100% Duty Cycle
1 200
80
9-14
23.0
0.42*
- - -
2.6
0.05*
2.6
0.03*
*While idling
Sense Voltage For Stick And TIG Lift Arct
NOTE: Duty cycle limitations on units with 115 volt input power are due to the input power cord supplied with the unit.