6-6. Stick Open-Circuit Voltage (OCV) Selection (All Models)
1 Process Switch Pad
2 Adjust Switch Pad
3 Amperage Switch Pad
4 Power Switch
To access the Stick OCV selection,
turn power switch on and then press
the Process, Adjust and Amperage
switch pads before the software ver-
sion clears the meters. Hold the switch
pads until [SEL] [Loc] or [SEL] [noc) appears.
5 Encoder Control
6 Meter Display
Turn Encoder to change between low
OCV [SEL] [Loc] and normal OCV [SEL]
[noc]. Active selection is displayed on
the meters.
When Stick low OCV is selected, open-
circuit voltage is between 9 and 14
volts. When Stick normal OCV is se-
lected, open-circuit voltage is approxi-
mately 80 volts.
Application: For most Stick applica-
tions use low open-circuit voltage. Use
normal open-circuit voltage for hard to
start Stick electrodes, or if required for
your particular application.