Owner`s manual
OM-2226 Page 52
B. Lockout Levels
. Before activating lockout levels, be
sure that all procedures and parame-
ters are established. Parameter adjust-
ment is limited while lockout levels are
active.
Level 1
. Remote amperage control is not avail-
able in level 1.
TIG Output Selection
If either the TIG HF Impulse or TIG Lift Arc
process (see Section 5-6) was active when
lockout level 1 was activated, the operator
can choose between RMT STD (Remote
Standard) or RMT 2T HOLD (Remote 2T
Hold) (see Section 5-8). The On function is
also available if TIG Lift Arc was active.
Stick Output Selection
If the Stick process was active when lock-
out level 1 was activated, the operator can
choose between RMT STD or On.
When parameter change or selection is lim-
ited by lock level 1, [LOCK][LEV1] is dis-
played as a reminder.
Level 2
. Remote amperage control is not avail-
able in level 2.
Includes all the functions of level 1 plus Pro-
cess Selection (see Section 5-6).
When parameter change or selection is lim-
ited by lock level 2, [LOCK][LEV2] is dis-
played as a reminder.
Level 3
. Remote amperage control is not avail-
able in level 3.
Includes all the functions of levels 1 and 2
plus the following:
+10% adjustment of preset TIG or Stick
Weld Amps
Select desired process, TIG or Stick, and
use Encoder control to adjust amperage +/−
10% of preset amperage value, up to the
limits of the machine. If operator tries to go
beyond the ±10%, the amperage (right) me-
ter will display [LOCK][LEV3] as a reminder.
Pulser ON/Off Control
Gives operator the ability to turn on/off the
Pulser control.
When parameter change or selection is lim-
ited by lock level 3, [LOCK][LEV3] is dis-
played as a reminder.
Level 4
Includes all the functions of levels 1, 2, and
3 plus the following:
Remote Amperage Control
Allows operator to use remote amperage
control if desired. Remote control operates
from minimum to maximum of preset am-
perage value. Connect remote control de-
vice according to Section 4-8.
When parameter change or selection is lim-
ited by lock level 4, [LOCK][LEV4] is dis-
played as a reminder.
Use Encoder Control To Adjust
Amperage ±10% Of Preset
Value.
L3
Levels 1, 2, And 3
Level 4
AJ
B
K
I
C
L
NH
D
M
G
E
F
Indicates which functions are available
for the corresponding lockout level.
L2 L1 L3