6-7. Lockout Functions
A. Accessing Lockout Capability
2
oFF
cod
1
oFF
Loc
See Section 5 for explanation of controls referred to in all of
Section 6-7.
There are four (1−4) different lockout levels. Each successive level
allows the operator more flexibility.
. Before activating lockout levels, be sure that all procedures and
parameters are established. Parameter adjustment is limited
while lockout levels are active.
To turn On the lockout feature, proceed as follows:
1 Encoder Control
2 Amperage (A) Switch Pad
Press Amperage (A) switch pad to toggle between the lock and code
displays. Toggle switch pad until code is displayed.
Turn Encoder control to select a lockout code number. The code
number will appear on the amp meter. Select any number from [1]
thru [999]. IMPORTANT: remember this code number, as you will
need it to turn the lockout feature off.
Toggle Amperage (A) switch pad until lock is displayed. You may now
select a lockout level.
There are four lockout levels available. Turn Encoder control to se-
lect a lockout level (see Sections 6-7B for lockout level descriptions).
Once the desired three digits have been entered and a lockout level
selected, exit advanced functions mode (see Section 6).
To turn Off the lockout feature, proceed as follows:
Use Encoder control to enter the same code number that was used
to turn on the lockout feature.
Press the Amperage (A) switch pad. The amperage (right) meter dis-
play will change to [OFF]. The lockout feature is now off.
Toggle
Select Code Number
Select Lockout Level
1 to 999
1, 2, 3, or 4