Owner`s manual
OM-2226 Page 47
F. 4T Momentary Operation
1 4T Momentary Meter Display
2 Encoder Control
To select 4T Momentary, turn Encoder control.
4T Momentary torch trigger operation is as shown.
. When a remote switch is connected to the welding pow-
er source, use the remote switch to control the weld
cycle. Amperage is controlled by the welding power
source.
Application:
Use 4T Momentary trigger method when the functions of a
remote current control are desired, but only a remote on/off
control is available.
rt
4tE
= 4T Momentary Main
Current (A)
Preflow
Initial Amps
Initial Slope
Final Slope
Postflow
Main Amps
Final Amps
1
. For first torch trigger push & release, if trigger is held more than 3 seconds, trigger cycle ends.
P/R
P/R P/R
P/R
P/R = Push and release trigger; * = Push and releasing during final slope will break the arc and go to postflow
P/R
*
2