Owner`s manual

OM-2226 Page 43
E. Changing Start Slope Time
1 Amperage Switch Pad
2 Encoder Control
3 Amps Meter
To adjust Start Slope Time proceed as fol-
lows:
Press Amperage switch pad. Switch pad
LED turns on, and meter S LED turns on.
The Start Slope Time is displayed in milli-
seconds on the amps meter, and can be ad-
justed (see Section 5-13) by turning the
Encoder control.
To change Preset Amperage Minimum,
proceed to Section F.
2
StS
20
3
Current (A)
Start Slope Time
1
F. Changing Preset Amperage Minimum
1 Amperage Switch Pad
2 Encoder Control
3 Amps Meter
To adjust Preset Amperage Minimum pro-
ceed as follows:
Press Amperage switch pad. Switch pad
LED turns on, and meter A LED turns on.
The Preset Minimum Amperage is dis-
played on the amps meter, and can be ad-
justed (see Section 5-13) by turning the
Encoder control.
. Whatever amperage is selected as the
preset amperage minimum, is the min-
imum amperage that the machine will
provide.
2
PA_
5
3
Current (A)
Preset Amperage Minimum
1