Owner`s manual
OM-2226 Page 36
5-12. Spot Time Control (Reconfigured RMT 2T HOLD Output Selection)
SPO
1.0
1
3
1 Spot Time Meter Display
Select Spot function according to
Section 6-3G.
2 Amperage Switch Pad
3 Encoder Control
Set spot parameters as follows:
Press Amperage switch pad once
(meter A LED turns on) and turn En-
coder to set spot amperage. Press
Amperage switch pad again, (meter
S LED lights) and turn Encoder to
set spot time (.1−25 seconds). Fac-
tory default setting is 1 second.
Application: To provide a timed
weld. Used for tacking, and thin
sheet joining.
2
5-13. Factory Parameter Defaults And Range And Resolution
Parameter Default Range And Resolution
PROCESS
* Stick OCV
TIG HF Impulse
Low OCV
TIG HF Impulse / TIG Lift / Stick
Low OCV / Normal OCV
*Stick Stuck Check ScI (On) ScI (On) / Sc0 (Off)
OUTPUT
RMT 2T
1
RMT STD
2T
RMT STD / RMT 2T / ON
RMT 2T can be reconfigured for: 2T / 4T / Mini Logic
/ 4T Momentary / Spot (see Section 6-3)
A MAIN / PEAK
DC TIG
DC STICK
150 A
110 A
1 − 200 Amps
1 − 200 Amps
Spot Time
**Weld Time
1.0 S
0 S
0.1 − 25.0 Seconds
Dual Range And Resolution
0.0 − 99.9 / 100 − 999 Seconds
PULSER
PPS
PEAK t
BKGND A
Off
100 Hz
40%
25%
ON / OFF
Dual Range And Resolution
0.1 − 9.9 / 10 − 500 Hertz
5 − 95 Percent
5 − 95 Percent
*Meter “PPP” Display −−− (Off) −−− (Off) / PPPP (On)
SEQUENCER
INITIAL A
**Initial Time
INITIAL SLOPE t
FINAL SLOPE t
FINAL A
**Final Time
20 A
0 S
0 S
0 S
5 A
0 S
1 − 200 Amps
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
1 − 200 Amps
0.0 − 25.0 Seconds