Owner`s manual
OM-2226 Page 15
4-3. Specifications
Input Power Rated Output
Welding
Amperage
Range
Max.
Open-Cir-
cuit Voltage
(U0)
Rated Peak Strik-
ing Voltage (Up)
Amperes Input At Rated Output,
50/60Hz
KVA KW
115 230 400 460
Three-Phase
Stick Process
150 A @ 26
VDC,
60% Duty
Cycle
1 − 200
80∇
9-14♦
15 KV**
-−
13.1
0.16*
7.4
0.24*
6.4
0.25*
5.2
0.06*
5.0
0.03*
Three-Phase
TIG Process
175 A @ 17
VDC,
60% Duty
Cycle
1 − 200
80
9-14♦
15 KV** -−
10.5
0.16*
6.0
0.24*
5.2
0.25*
4.2
0.06*
4.0
0.03*
Three-Phase
Stick Process
200 A @ 28
VDC, 30%
Duty Cycle
1 − 200
80∇
9-14♦
15 KV** 18.4
0.16*
10.3
0.24*
8.9
0.25*
7.3
0.06*
7.0
0.03*
Three-Phase
TIG Process
200 A @ 18
VDC, 40%
Duty Cycle
1 − 200
80
9-14♦
15 KV**
12.7
0.16*
7.2
0.24*
6.2
0.25*
5.1
0.06*
4.9
0.03*
Single-Phase
Stick Process
150 A @ 26
VDC,
60% Duty
Cycle
1 − 200
80∇
9-14♦
15 KV**
-−
21.7
0.23*
-−
10.6
.25*
5.0
0.05*
5.0
0.02*
Single-Phase
TIG Process
175 A @ 17
VDC,
60% Duty
Cycle
1 − 200
80
9-14♦
15 KV**
-−
17.4
0.23*
-−
8.5
.25*
4.0
0.05*
4.0
0.02*
Single-Phase
Stick Process
125 A @ 25
VDC,
50% Duty
Cycle
1 − 200
80∇
9-14♦
15 KV**
34.1
0.42*
-−
-− -−
4.0
0.05*
3.8
0.03*
Single-Phase
TIG Process
150 A @ 16
VDC,
70% Duty
Cycle
1 − 200
80
9-14♦
15 KV**
29.7
0.42*
-−
-− -−
3.4
0.05*
3.4
0.03*
Single-Phase
Stick Process
100 A @ 24
VDC,
80% Duty
Cycle
1 − 200
80∇
9-14♦
15 KV**
28.1
0.42*
-− -− -−
3.2
0.05*
3.2
0.03*
Single-Phase
TIG Process
125 A @ 15
VDC,
100% Duty
Cycle
1 − 200
80
9-14♦
15 KV**
23.0
0.42*
-− -− -−
2.6
0.05*
2.6
0.03*
*While idling
** Arc starting device is designed for manual guided operations.
♦Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
∇Normal open-circuit voltage (80 volts) is present while in Stick with normal open-circuit voltage selected.
. Duty cycle limitations on units with 115 volt input power are due to the input power cord supplied with the unit.
.
This unit is equipped with Auto-Linet. The Auto-Line circuitry automatically connects to 120−460 VAC, single- or three-phase power with-
out removing the cover to relink the power source.