Specification

2
AIRFLOW
CMF95 Maximum Airflow & Temperature Rises
ModelNumber
&HeatingInput
(BTUH)
MotorSpeed
ExternalStaticPressure(InchesWaterColumn)
0.1 0.2 0.3 0.4 0.5
CFM Rise CFM Rise CFM Rise CMF Rise CFM Rise
CMF95045
45,000
HIGH* 1380 29 1335 30 1290 31 1230 32 1175 34
MEDHIGH 1350 29 1295 31 1240 32 1190 33 1135 35
MEDLOW 1100 36 1055 38 1020 39 975 41 920 43
LOW** 1000 40 970 41 935 42 900 44 860 46
CMF95072
72,000
HIGH* 1485 43 1440 44 1390 46 1340 47 1290 49
MEDHIGH** 1263 50 1235 51 1205 53 1160 55 1115 57
MEDLOW 1130 56 1100 58 1175 54 1045 61 1000 63
LOW 880 72 846 75 830 76 805 79 770 82
NOTES:
*FactorySetCoolingSpeed
**FactorySetHeatingSpeed
1.Temperaturerises(°F)inthetableareapproximate.Actualtemperaturerisesmayvary.
2.Temperaturerisesshadedingrayareforreferenceonly.Theseconditionsarenotrecommended.
3.Airflowperformanceiswithalter.
SPECIFICATIONS
CMF95 045 CMF95 072
Input(BTUH)* 45000 72000
HeatingCapacity(BTUH) 42750 68400
AFUE(%) 95.1 95.1
BlowerDxW(in.) 11x8 11x8
MotorHP-Speed-Type 1/2-4-PSC 1/2-4-PSC
MotorFLA(Amps) 8.60 8.00
RatedExt.SP(in.WC) 0.3 0.3
TemperatureRiseRange(°F) 25-55 30-60
FuseorBreaker(Amps) 20 15
ShippingWeights(lbs)
150 155
Note:Allmodelsare115V,60Hz,1phase.GasConnectionsare1/2”NPT.
AFUE=AnnualFuelUtilizationEfciency
*Ratingsto2,000ft.Over2,000ft.reduce4%foreach1,000ft.above
sealevel.
FURNACE COMPONENTS
Blower Assembly
Inducer Assembly
Gas Valve
Gas Manifold &
Burner Assembly
Blower Switch
Control Board
Limit Switch
Inline Drain
Assembly
24V Transformer
Igniter
Main Air Limit Switch
Flame Sensor
Roll-Out Switch
Combustion Air Pipe
Exhaust Vent Pipe