Specifications
G.
Maintenance
and
TroubleshootiNg
61
Routine
Maintenance
A
Disconnect
power
before
maintaining.
S
~
~
Maintain
more
often
during
severe
conditions.
3
Months
Blow
out
or
vacuum
inside.
Clean
and
tighten
weld
terminals.
62
Troubleshooting
Trouble
Remedy
No
weld
output;
fan
does
not
run.
Place
line
disconnect
switch
in
On
position
(see
Section
4.5).
Check
and
replace
line
fuse(s),
if
necessary,
or
reset
circuit
breaker
(see
Section
4.5).
Check
for
proper
input
power
connections
(see
Section
4.5).
No
weld
output;
fan
on.
Be
sure
Range/Polarity
switch
is
not
set
between
positions.
Tighten
remote
control
connection
to
Remote
14
receptacle.
Check
remote
control
(see
remote
control
Owners
Manual).
Unit
overheated.
Allow
unit
to
cool
(see
Section
3.3).
Fan
not
operating;
weld
output
available.
Check
for
and
remove
anything
blocking
fan
movement.
Have
Factory
Authorized
Service
Agent
check
fan
motor.
Replace
unreadable
labels.
Replace
0-ring
~fl
Electrode/Gas
Output
receptacle
if
cracked.
6
Months
Or
18
OM-167
439