Specifications

POWERED AIR PURIFYING RESPIRATOR
OM-235 936 Page 18
Battery run time is too
short.
Replace battery.
Check air filter and replace if necessary (see Sections 2-4 and
2-7). A clogged air filter element reduces battery life.
Danger light is On, alarm
sounds or blower vibrates.
Continue wearing the respirator and leave the contaminated area
immediately. Check blower air flow (see Sections 2-4 and 2-7).
Remove blockage from blower outlet and/or hose. If alarm sounds
or blower vibrates continuously, contact a Factory Authorized
Service Agent.
Remove packaging from air filter.
Have Safety Director and an Industrial Hygienist determine if you
are using the proper equipment for the work environment.
Air supplied to hood
smells and tastes unusual;
eyes and throat irritation.
Continue wearing the respirator and leave the contaminated area
immediately. Check contamination level of filter, and replace filter
if necessary.
Check hose connections to blower and hood.
Verify spark guard, prefilter, and particulate (HEPA) filter are
installed in blower assembly.
Have Safety Director and an Industrial Hygienist determine if you
are using the proper equipment for the work environment.
Blower supplies insuffi-
cient air to hood.
Check hose connections to blower and hood.
Remove blockage from blower outlet and/or hose.
Check air filter and replace if necessary (see Sections 2-4 and
2-7). A clogged air filter element reduces battery life.