Owner`s manual

OM-223 528 Page 27
SECTION 6 SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
.
For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
5-7.
If time is set to zero in any timed
sequence, the sequence is skipped.
. Maximum IPM may actually be
lower depending on the process
and wire type selection.
Volts/Arc
Adjust
IPM Seconds
2. Postflow Off-10.0
1. Preflow Off-10.0
Sequence Parameters
3. Start
4. Crater
Off-5.0
Off-5.0
10.0-44.0/
0-99
50-1400*/
0-99
10.0-44.0/
0-99
50-1400*/
0-99
Wire Speed
Time
Start
Time
Preflow
Weld WFS
Weld Time
Crater WFS
Crater
Time
Postflow
Time
Time
PostflowCrater
Weld
Preflow
Sequence
End
Output
Program
Relay Energized
Arc
Strike
Relay Not Energized
Example: output relay A and B can be set to
turn On at arc strike and Off at crater.
5. Weld
— — — —
— — — —
— — — — Infinite-999.9
5. Retract
— —
50-1400*
Off-1.0
* Mimimum setting is 50 IPM or lowest taught point of a program.
Retract