Owner`s manual

OM-223 528 Page 24
5-8. Setting Output Relay A And Outut Relay B
When the Feeder Set Up button is pressed
once, the Sequence LED will illuminate and
the upper display will show sequence
options. See Section 5-7 for set up
procedures.
Pressing the Feeder Set Up button a
second time will display Output A option,
and the Lower Display push-button LED will
illuminate. Rotate the Adjust knob to turn
Output A option on or off. When Output A is
on the Output A LED will illuminate.
If Output A option is turned on, the upper
display LED will begin flashing. Pressing the
Upper Display button allows selecting on/off
sequences in the weld program. Rotate the
Adjust knob to cycle through the
sequences. The sequences are set up in a
weld program as follows:
Arcstrike (ARC) and Sequence End are not
time dependent and are always present in a
weld program.
Weld (WELD) may or may not be time
dependent, but it is always present in a weld
program.
Preflow (PRE), startpower (STRT), crater
(CRTR), and postflow (POST) are time
dependent and may or may not be present
in a weld program.
If a sequence was not enabled by setting a
time value while in the sequence option (see
Section 5-7), the sequence will appear as
DISA (disabled). When a sequence is
disabled, the output relay cannot be set.
Pressing the Lower Display push button
allows setting a sequence on or off. if no
change is desired, dashes (−−−−) must be
selected. Pressing the Upper Display push
button or the Feeder Set Up button confirms
choices.
Pressing the Feeder Set Up button again
will display Output B option. To set Output B,
follow the same procedure listed previously
for Output A.
Pressing the Feeder Set Up button again
will exit the Sequence menu and return the
system to standby mode.
Wire Speed
Time
Start
Time
Preflow
Weld WFS
Weld Time
Crater WFS
Crater
Time
Time
Crater
Weld
Preflow
Arc
Strike
Sequence Diagram
Postflow
Time
Postflow
Sequence
End
Retract