OM-223 528 Page 15
4-9. Connections To AROI Receptacle RC100 (See Section 4-10 For Additional
Information)
RC100 Pin I/O Cable Lead Number Connection
A 11 Output A normally-open
B 9 Program select input C
C 2 Contactor On input
D 6 Output B normally-open
E None No connection
F 12 Program select input B
G None No connection
H None No connection
J 4 Error output normally-open
K 3 Relay common
L 1 Input common
M 8 Program select input A
N 7 Arc established output normally-open