Owner`s manual
. A complete Parts List is available at www.MillerWelds.com
OM-242 880 Page 23
4-17. Generator Settings For Plasma Cutter Operation
Ref. 803 222
! Engine Control Switch must be set at
“RUN” position − not “RUN/IDLE”.
! Set generator Fine Adjustment Control to 10
for maximum auxiliary power, if applicable.
. The peak kW at arc stretch of this plasma power source is
15.5 kW. Reducing output to 45 amps may be necessary
to operate the unit using a 10 kW generator.
Notes