OM-242 880 Page 21
4-15. Wiring Optional 240 Volt Plug (119 172) For Connection To Miller Bobcat,
Trailblazer Or Hobart Champion 10,000
Ref. 120 813-D / Ref. 805 161-A
Tools Needed:
3/16 in.
1
Check input voltage available at the
power supply.
. The Auto-LineE circuitry in this
unit automatically adapts the
power source to the 240 volts,
single-phase, 50 or 60 Hz
primary voltage from the power
supply.
1 Input And Grounding
Conductors
2 Plug Wired for 240 V, 2-Wire
Load
3 Neutral (Brass) Terminal And
Prong (Not Used)
4 Load 1 (Brass)Terminal And
Prong
5 Load 2 (Brass) Terminal And
Prong
6 Ground (Brass) Terminal And
Prong
7 Black And White Input Con-
ductors
8 Red Input Conductor
9 Insulation Sleeving
10 Electrical Tape
11 Green Or Green/Yellow
Ground Conductor
Insulate and isolate red conductor
as shown.
! Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.
7
1
10
9
8
Green Or
Green/Yellow
11
2
3
4
5
6
240V
11
7
6
5
4
3
Plug Front