Owner`s manual
. A complete Parts List is available at www.MillerWelds.com
OM-242 880 Page 19
4-13. Connecting 1-Phase Input Power
input1 20008−01 − 803 766-C / 805 159
NOTICE − The Auto-Line circuitry in this
unit automatically adapts the power
source to the primary voltage being ap-
plied. Check input voltage available at site.
This unit can be connected to any input
power between 208 and 230 VAC without
removing cover to relink the power
source.
1 Black And White Input Conductor
(L1 And L2)
2 Red Input Conductor
3 Green Or Green/Yellow Grounding
Conductor
4 Insulation Sleeving
5 Electrical Tape
Insulate and isolate red conductor as
shown.
6 Input Power Cord.
7 Disconnect Device (switch shown in
the OFF position)
8 Disconnect Device Grounding
Terminal
9 Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to
disconnect device line terminals.
10 Over-Current Protection
Select type and size of over-current
protection using Section 4-11 (fused dis-
connect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
1
6
5
4
2
7
6
L1
L2
1
=GND/PE Earth Ground
3
3
1
8
9
10
Tools Needed:
Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.
Always connect green or green/
yellow conductor to supply
grounding terminal first, and never
to a line terminal.