4-12. Extension Cord Data
. When calculating max. cord length, remember to include conductor length from line disconnect device to input power receptacle.
Input Voltage
Input Power
Phase
Hertz
Fuse Size Or
Circuit Breaker Rating
Conductor Size Max. Cord Length
208 V 1 50/60
Time-Delay
2
50 A
Normal Operating
3
70 A
10 AWG 55 ft (17 m)
230 V 1 50/60
Time-Delay
2
50 A
Normal Operating
3
60 A
10 AWG 67 ft (21 m)
208 V 3
50/60 Time-Delay
2
30 A
Normal Operating
3
40 A
12 AWG 68 ft (21 m)
230 V 3
50/60 Time-Delay
2
30 A
Normal Operating
3
35 A
12 AWG 83 ft (25 m)
380 V 3
50/60 Time-Delay
2
15 A
Normal Operating
3
20 A
14 AWG 148 ft (45 m)
460 V 3
50/60 Time-Delay
2
15 A
Normal Operating
3
20 A
14 AWG 216 ft (66 m)
575 V 3
50/60 Time-Delay
2
10 A
Normal Operating
3
15 A
14 AWG 341 ft (104 m)
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).