Performance Data
Control Panel
Input
Power
Three-
Phase
Rated Output
450 A at 38 VDC,
100% Duty Cycle
565 A at 43 VDC,
60% Duty Cycle
Amperage
Range in
CC Mode
5–600 A
Voltage
Range in
CV Mode
10–38 V
Max. Open-
Circuit
Voltage
95 VDC
Amps Input at Rated Load Output, 60 Hz
230 V 400 V 460 V 575 V KVA KW
50.8 31 27.8 24.4 21.2 19.2
Weight
118 lb
(53.5 kg)
Dimensions
H: 17 in (432 mm)
W: 14-1/2 in (368 mm)
D: 26 in (660 mm)
Specifications (Subject to change without notice.)
Certified to both the Canadian and U.S. Standards for welding equipment.
Additional Features
Primary voltage display shows what primary
voltage the power source is linked for without
removing the side panels. Saves time and
assures you that the power source has been
correctly linked for available input voltage.
Unique case design helps protect internal
components from dirt and dust. To connect
input power cord and/or set unit up for correct
input power, remove the easy-to-handle panel
(1/3 case). The remaining two-thirds of the
case never needs to be removed!
Optional remote on/off provides ability to turn
power source on or off when it is located away
from your work.
1. Voltmeter
2. Power On/Off Switch
3. Inductance Control
4. Remote On/Off Receptacle (Optional)
5. Ammeter
6. Voltage Adjustment Control
0
150
100
200
300
400
500
600
10 15 20 25 30 40 50 60 70 80 90 100
WELD AMPS
% DUTY CYCLE
DUTY CYCLE CHART
3-PHASE
OPERATION
CV VOLT/AMP CURVES
MAX.
MIN.
100
80
60
40
20
0
AMPERAGE
VOLTAGE
0
100 200 300 400
500
600 700