Owner`s manual
OM-243 477 Page 30
7-4. TIG Welding Mode - GTAW Process
! Weld terminals are energized
through the remote control in TIG
welding mode.
1 Mode Switch
2 Left Display
3 Right Display
4 Amps Indicator
5 Adjust Control
Setup
For typical system connections refer to
Section 7-1.
Rotate Mode Switch to TIG position as
shown.
The preset amperage is shown in the Right
Display with the Amps Indicator lit.
Operation
The Adjust Control is used to set desired
preset amperage.
A remote control is required to turn on the
weld output.
. If the remote control has an amperage
adjustment, the adjustment will func-
tion as a percentage of the preset am-
perage.
. For best results, gently scratch the
tungsten electrode to the work to initi-
ate an arc. To minimize arc flare at the
end of the weld, pull back the electrode
quickly to extinguish the arc.
2
1
3
4
5
8 5
243 478-A