Owner`s manual
OM-243 477 Page 26
6-3 Configuration Option Menu (Continued)
V-Sense Feeder Weld Process
This option enables MIG (V.SEN MIG) or
Pulsed MIG (V.SEN PULS) when the Mode
Switch is in the VSENSE FEEDER posi-
tion. See Section 8-2 for MIG operation or
Section 8-4 for Pulsed MIG operation.
Pulsed MIG Manual/Auto Control
This option sets the PULSED MIG control
as manual (PULS MAN) or Auto (PULS
AUTO) operation. When set to manual op-
eration, the arc length setting on power
source and wire speed setting on wirefeed-
er need to be adjusted independently to
achieve the desired arc length. When set to
Auto operation, once arc length is deter-
mined it is not necessary to change the arc
length value with changes in wirefeed
speed.
The XMT 350 MPa and synergic feeders al-
low single knob control of the arc. As wire-
feed speed is increased or decreased, the
pulse parameters increase or decrease
matching the power output to the wire
speed.
. Auto Operation will only work with syn-
ergic wirefeeders. All other wirefeeders
will only operate as manual control.
Even when Auto is displayed, opera-
tion will be manual when any other
feeder is connected. See product liter-
ature for a list of compatible synergic
feeders.
Pulsed MIG Adjustment
This option allows adjusting the Pulsed MIG
process in units of Arc Length (PULS
ARC.L) or preset voltage (PULS VOLT).
Panel and Remote Adjustment
When the Mode Switch is set to SCRATCH
START TIG, LIFT−ARC TIG, or STICK, the
remote command behavior is configurable.
SCRATCH START TIG and LIFT−ARC TIG
default to panel and remote (PANL RMT)
amperage adjustment but can be config-
ured for panel only (PANL ONLY) adjust-
ment. The default amperage adjustment for
STICK is panel only (PANL ONLY) but can
also be configured for panel and remote
(PANL RMT) adjustment. All other Mode
Switch positions are non−configurable and
allow both panel and remote (PANL −RMT)
adjustment.
. Panel adjustment is made using the
Adjust Control on the front panel. Re-
mote adjustment is made using a re-
mote control device connected to the
Remote 14 Receptacle.
PULS
ARC.L
PANL
RMT
PULS
AUTO
V.SEN
MIG