Owner`s manual
OM-243 477 Page 21
5-8. Remote 14 Receptacle Information
AJ
B
K
I
C
L
NH
D
M
G
E
F
Socket* Socket Information
24 VOLTS AC
A 24 volts AC. Protected by supplementary protect-
or CB2.
B Contact closure to A completes 24 volts AC
contactor control circuit.
115 VOLTS AC
I 115 volts AC. Protected by supplementary pro-
tector CB1.
J Contact closure to I completes 115 volts AC
contactor control circuit.
REMOTE
OUTPUT
CONTROL
C Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D Remote control circuit common.
E 0 to +10 volts DC input command signal from
remote control.
L Wirefeed speed command, 0 to +10 volts DC out-
put signal from wirefeeder.
N Wirefeed speed common.
A/V
AMPERAGE
VOLTAGE
F Current feedback; +1 volt DC per 100 amperes.
H Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
GND
G Circuit common for 24 and 115 volts AC circuits.
K Chassis common.
*The remaining sockets are not used.
803 691-C
1 115 V 60 Hz 10 Amp AC
Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 5-8).
2 Supplementary Protector CB1
3 Supplementary Protector CB2
CB1 protects duplex receptacle
and 115 volts AC portion of Remote
14 receptacle from overload.
CB2 protects 24 volts AC portion
of Remote 14 receptacle from
overload.
Press button to reset supplement-
ary protector.
2 3
1
5-9. 115 Volts AC Duplex Receptacle And Supplementary Protectors