User Manual
Table Of Contents
- RK-5409-5 Reference Kit for 916 MHz MeshScape™ Systems
- Contents
- About This Guide
- 1: Introduction
- 2: Installing the MeshScape System
- 3: Running MeshScape Network Monitor
- MeshScape Network Monitor Overview
- Configuring a Node’s Operation
- Configuring Sample Interval of Single Node
- Configuring Sample Interval of all Network Nodes
- Configuring Digital I/O Operation
- Configuring UART Operation
- Configuring AD (analog-to-digital) Converter Operation
- Configuring RS-232 Operation (MN-5409 only)
- Configuring RS-485 Operation (MN-5409 only)
- Using Watch Function to Display Configuration Information
- Labeling an End Node or Mesh Node
- Configuring Persistence Attributes
- Selecting a Com Port on the Host PC
- Configuring Serial and ADC Data Formats
- Turning Event Tracking On/Off
- Broadcasting Data to All Nodes.
- Creating an Event Log File
- Viewing the Contents of an Event Log File
- Viewing MeshScape Statistics
- 4: Using the MeshScape API
- A: Sample Application
- B: Performing Firmware Upgrades and Configuring Device IDs
- Glossary
- Index
RK-5409-5 Reference Kit User’s Guide A-7
Changing Temperature Sensor Battery
Changing Temperature Sensor Battery
The temperature sensor assembly comes with a factory installed lithium battery. The procedure
below describes how to replace the battery when needed. Millennial Net recommends using
the following replacement battery type:
DigiKey Part Number: P189-ND.
To replace the battery (see Figure A-6):
1. Use an Allen wrench to turn in the two set screws holding the cover to the base and
remove the cover.
2. Turn the power switch OFF.
3. Remove the screws (2) securing the terminal board to the base and lift the terminal up
and off the base.
4. Replace the battery—located on the bottom of the terminal board—with the
recommended battery type, observing polarity (+ side of battery to + side of holder).
5. Turn the power switch ON.
6. Reinstall the terminal board, replace assembly cover, and back out the two cover set
screws to secure the cover in place.
Figure A-6. Changing temperature sensor assembly battery
Caution
Do not overtighten the terminal board mounting screws, which may damage the battery holder.
Replace battery
4
Turn power switch ON
5
Turn power switch OFF
2
Turn in cover set screws (2),
1
then remove cover
Remove mounting screws (2)
and terminal board
3
Replace cover
6