User's Manual

Table Of Contents
2-12 Millennial Net
Installing the MeshScape System
End Node Setup (EN-5424)
The End Nodes, model number EN-5424, are mounted to terminal boards as shown in Figure
2-8. A terminal board provides easy access to I/O connections and the power switch. The
terminal board also contains a battery holder and battery for supplying power to the End Node.
The label on top of the End Node contains the device and group IDs assigned to the End Node.
Figure 2-8. End node and terminal board (top and bottom views)
To provide power to the End Node, a 3 VDC lithium coin cell (CR2450 type) is provided and
already installed in the battery holder on the back of the terminal board.
To activate an end node:
Turn the terminal board's power switch ON (refer to Figure 2-8). The End Node is ready to
communicate directly or indirectly (through an Mesh Node) with the MeshGate. Repeat
this step for each End Node.
Note:
C
Configuring and connecting an End Node or Mesh Node to external devices via their
digital or analog I/O connectors is discussed in
Chapter 3, “Running MeshScape
Network Monitor”.
End Node
Terminal Board
Digital I/O
Terminals
RS-232/RS-485
Connector
On/Off
Switch
Group ID
Device ID
Lithium Coin Cell Holder
3VDC Lithium Coin Cell
Analog I/O
Ter mi na ls
P8 Programming Port
Used with MeshScape
Programmer Application