User's Manual

Table Of Contents
B-4 Millennial Net
Using the Module Programming Terminal Board
A terminal board is included in your Installation Kit for programming end node or mesh node
modules. This module programming terminal board is shown in
Figure B-3.
Figure B-3.Module programming terminal board
To program an end node or mesh node module using this terminal board:
1. With switch SW1 in the Off position, connect the end node or mesh node module to
connector P11 on the module programming terminal board.
2. Referring to Figure B-2 and using the supplied MeshGate programming cable and
MeshGate-to-end node adapter, connect the external programming port on the
MeshGate to port P8 on the module programming terminal board.
Ensure that Pin 1 on the MeshGate-to-end node adapter mates with Pin1 on connector
P8 when making this connection.
3. Remove the 3.3v lithium battery on the back side of the module programming terminal
board.
4. Connect the external power adapter cable supplied in your Installation Kit to connector
P7 on the module programming terminal board.
5. Connect the supplied AC adapter to the external power adapter cable, and then plug the
AC adapter into a 110/220 VAC power source.
6. Move switch SW1 to the On position.
Connect Node to P11
On/Off Switch
Connect External Power
Adapter Cable to P7
P8
Programming Port
External Power
Adapter Cable