User Manual

Table Of Contents
EK-5209-5 Evaluation Kit User’s Guide 3-19
Configuring a Node’s Operation
Configuring RS-485 Operation (RT-5209 only)
The RS-485 interface of the i-Bean Router operates using the following parameters:
Half-duplex mode
9600 baud
Transmitting data: Maximum byte length for one request is 80 bytes
Receiving data: Reception is terminated by the router when the maximum input byte
length is reached or there is no input for more than 20 ms. Once the input is terminated,
the data is transferred to iB-5209 Network Monitor.
The following procedure describes the steps that need to be taken to set up the hardware and
configure an i-Bean Router for RS-485 operation (see Figure 3-10):
1. Connect the network device to the standard 2-position RS-485 terminal block using the
pinout information provided in Figure 3-10. The terminal block will accept 26 AWG to 16
AWG wire.
2. From iB-5209 Network Monitor, select Edit>Devices. The Edit Device window displays.
3. Enter the device ID of the desired i-Bean Router and click Set. The Edit Device window is
now ready to make any changes to the selected i-Bean Router.
4. From the Digital I/O panel, select Serial Data: RS-485, then Update. The RS-485
connector is ready for operation (digital function is disabled).
5. (optional) To send serial data to the i-Bean Router, enter the data in the Serial Data panel,
then select Send Data.
Figure 3-10. Configuring i-Bean Router for RS-485
Connect signals
1
Select node
3
Select Edit>Devices
2
(optional) Enter serial data,
5
then select Send Data
Select RS-485,
4
then select Update