User Manual

Table Of Contents
3-8 EK-5209-5 Evaluation Kit User’s Guide
iB-5209 Network Monitor Operations
F AD Converter This panel is used to control the states of the AD (Analog-to-Digital)
Converter channels.
For details, see ’Configuring AD (analog-to-digital) Converter Operation’
on page 3-17.
G Serial Interfaces This panel is used to select a serial I/O operation for a device: Digital
UART, RS-232 (RT-5209 only), or RS-485 (RT-5209 only). Selecting serial
operation disables digital I/O functionality.
For details, see the following:
’Configuring UART Operation’ on page 3-15
’Configuring RS-232 Operation (RT-5209 only)’ on page 3-18
’Configuring RS-485 Operation (RT-5209 only)’ on page 3-19
H Multiple Capture Multiple capture is a special feature that enables iB-5209 Network
Monitor to report the surrounding router information of a given device
(an i-Bean Endpoint or an i-Bean Router that has endpoint functionality).
For details, see ’Enable Multiple Capture’ on page 3-28.
I Serial Data This panel, which is only used if the node is configured for serial
operation, is used to send serial data to the node and configure the
length of the string sent.
For details, see the following:
’Configuring UART Operation’ on page 3-15
’Configuring RS-232 Operation (RT-5209 only)’ on page 3-18
’Configuring RS-485 Operation (RT-5209 only)’ on page 3-19
J Update/Close Update: Updates the selected device with any changes made to its
configuration.
Close: Closes the Edit Device window. If changes where made to the
device configuration and Update was not selected before selecting
Close, the changes will be ignored.
Table 3-1. Edit Device window functions (continued)
Item Description Function