User Manual

Table Of Contents
EK-5209-5 Evaluation Kit User’s Guide 3-5
iB-5209 Network Monitor Overview
Interval: Time of the last message generated by a node. This value is synchronized with
the sampling interval of the node. Time is displayed in either seconds (s) or minutes (m).
RX Packets: Number of packets successfully delivered to iB-5209 Network Monitor from a
node since the node was detected by the i-Bean Gateway. The counter is reset if one of
the following actions occur:
The node is powered down.
The i-Bean Gateway is powered down.
An i-Bean Router used as a network hop is powered down.
iB-5209 Network Monitor program is restarted.
Up/Down Time: Time since the node was first detected by the i-Bean Gateway.
Hop Count: Number of network node hops taken by a packet delivered from a node to
the i-Bean Gateway. For example: i-Bean Endpoint—i-Bean Gateway = 1 hop,
i-Bean Endpoint—i-Bean Router—i-Bean Gateway = 2 hops (each additional i-Bean Router
will add another hop).
First Hop: Device ID of the first i-Bean Router on the path used by a packet to get to the
i-Bean Gateway. If no i-Bean Router was used, then Direct will display, indicating the
device is communicating directly with the i-Bean Gateway.
Last Hop: Device ID of the last i-Bean Router on the path used by a packet to get to the
i-Bean Gateway. If no i-Bean Router was used, then Direct will display, indicating the
device is communicating directly with the i-Bean Gateway.
Voltage: DC voltage level of the node’s power source in volts.
ADC Data: Input voltages on pins used for analog-to-digital conversion operation.
DIO Data: Digital information on pins used for digital I/O operation.
Serial Data: Input serial data information when configured for serial operation.
Version: Version of firmware loaded on the node.