27
Counter
When pulse counter reaches a specific value. This only works when DI works
as counter mode.
Channel/4-20m
A/0-10V/PT100
When the value reaches any threshold.
Is continued for: the analog value should last for some time.
Set lockout time: after the lockout time, UC300 device will detect if analog
value matches the condition. 0 means this IF condition will only be detected
once.
Note: for UC300 cellular version, if this Modbus channel quantity is more than
1, this condition will only judge the first value.
Received a
message
When UC300 device receive a specific message from server.
The Device
Restarts
Reboot the device.
Received a D2D
control
command
This only works with UC300 LoRaWAN
®
version and the LoRa D2D feature is
enabled. See details on
chapter 4.5.
The signal
strength is weak
When UC300 cellular signal is lower than 10 asu, this only works with UC300
cellular version.
3. Set THEN action according to your request. You can add at most 3 actions in one command.
Action
Description
Send a custom
message
Send a custom message to the server.
Output Trigger
DO can be set to normally open/normally closed/change status.
Delay Time: this action will trigger after a specific time;
Duration: the output status will last for a specific time, 0 means permanent.
Restart the Device
Reboot the device.
Send a D2D control
command
This only works with UC300 LoRaWAN
®
version and the LoRa D2D feature is
enabled. See details on
chapter 4.5.
Send a Modbus
command via
RS485 interface
This only works with UC300 LoRaWAN
®
version and the LoRa D2D feature is
enabled. See details on
chapter 4.5.
Send a device
status message
This only works with UC300 cellular version and the SMS Report feature is
enabled.