User Guide
Table Of Contents
14
Installation Note:
In order to provide the best data transmission, please ensure the device is within the signal
range of the LoRaWAN
®
gateway and keep it away from metal objects and obstacles.
Avoid strong light, like direct sunlight or IR LED, in the detection area.
Do not install the device close to glass or mirror.
After installation and adjustment, please remove the protective film.
Do no touch the lens of sensor directly to avoid leaving the fingerprint on it.
The detecting performance will be affected if there’s dust on the lens. Please use the mirror
cleaning cloth to clean the lens if needed.
The device must be placed in a horizontal position on the top of the object so that it has a
clear path to the object.
When using waste bin mode, place the device in the center of waste bin and here are some
recommended sizes of waste bins: when the height is 40cm, the minimum radius should be
10cm; when the height is 80cm, the minimum radius should be 19cm.
5. Device Payload
All data are based on following format (HEX), the Data field should follow little-endian:
Channel1
Type1
Data1
Channel2
Type2
Data2
Channel 3
...
1 Byte
1 Byte
N Bytes
1 Byte
1 Byte
M Bytes
1 Byte
...
For decoder examples please find files on https://github.com/Milesight-IoT/SensorDecoders.
5.1 Basic Information
EM400-TLD reports basic information of sensor whenever it joins the network.
Channel
Type
Description
ff
01(Protocol Version)
01=>V1
09 (Hardware Version)
01 40 => V1.4
0a (Software Version)
01 14 => V1.14