User Guide

10
3.3 Basic Settings
Go to Device > Setting > General Settings to change the reporting interval, etc.
Parameters
Description
Device Mode
Select from “Standard Mode or “Bin Mode”.
Reporting Interval
Reporting interval of transmitting data to network server.
Standard Mode: 10 minutes as default;
Bin mode: 20 minutes as default.
Installation Height
Enable or disable the installation height of the device when in Bin Mode.
Note:
1. It is suggested to enable this feature if the bin is located under strong
light and there are bags inside the garbage bin.
2. If the collected value is above the installation height twice, the sensor
will report the installation height.
Value of the
Installation Height
Set the installation height between device and the bottom of waste bin.
Range: 0.02 - 3.5m.
Tilt & Distance
Switch
When detecting that the offset angle is greater than 20 degrees, turn off
the distance measurement.
Change Password
Change the password for ToolBox App or software to read/write this
device.
3.4 Threshold Settings
Go to
Device > Setting > Threshold Settings to enable the threshold settings and input the
distance threshold. EM400-TLD will detect whether the distance reaches the threshold
according to collecting interval. If threshold is triggered, it uploads the current data once
instantly.