User Guide

19
010-Bin Mode
Bit6=0
Bit7:
0 - disable threshold dismiss report
1 - enable threshold dismiss report
70 (Set Height Threshold in
Parking Lot Mode)
2 Bytes, unit: mm
77 (Set Installation Height)
2 Bytes, unit: mm
Example:
1. Set reporting interval as 20 minutes.
ff03b004
Channel
Type
Value
ff
03 (Set Reporting Interval)
b0 04 => 04 b0 = 1200s = 20 minutes
2. Reboot the device.
ff10ff
Channel
Type
Value
ff
10 (Reboot)
ff (Reserved)
3. Set the device as standard mode.
ff7100
Channel
Type
Value
ff
71 (Set Device Mode)
00 = Standard Mode
4. Enable “Tilt & Distance Switch feature.
ff3e01
Channel
Type
Value
ff
3e (Set Tilt & Distance Switch)
01 = Enable
5. When the distance is below 20cm or above 80cm, the sensor will send threshold alarm.
ff3e 8c c800 2003 0000 0000
Channel
Type
Value
ff
06 (Set Threshold Alarm)
CTRL: cc=10 001 100
100=below or above
001=standard mode
10=enable threshold dismiss
report