Multifunctional Ultrasonic Distance Sensor Featuring LoRaWAN® EM400-MUD User Guide
Safety Precautions Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. The device must not be disassembled or remodeled in any way. In order to protect the security of the device, please change the device password when first configuration. Default password is 123456.
Contents 1. Product Introduction ......................................................................................................................... 4 1.1 Overview ...................................................................................................................................4 1.2 Features ................................................................................................................................... 4 2. Hardware Introduction .....................................
1. Product Introduction 1.1 Overview EM400-MUD is a multifunctional ultrasonic distance sensor with small blind spot. Besides a wide measuring rage, EM400-MUD is equipped with three pre-set modes including standard mode, trash bin mode, and parking lot mode for different applications. Featuring low power consumption LoRaWAN® technology, EM400-MUD can work for over 10 years with its two built-in 9000 mAh batteries.
2.2 Hardware Overview 2.3 Dimensions (mm) 2.4 Power Button EM400-MUD can be switched on/off via NFC. Besides, users can use power button to switch on/off and reset the device manually. Function Action LED Indication Switch On Press and hold the button for more than 3 seconds. Off → On Switch Off Press and hold the button for more than 3 seconds. On → Off Reset Press and hold the button for more than 10 seconds. Quickly Blinks Check On/Off Status Quickly press the power button.
4. Basic information and settings of devices will be shown on ToolBox if it’s recognized successfully. You can switch on/off, read and write the device by tapping the button on the Apps. In order to protect the security of devices, password validation is required when configuring via unused phone. Default password is 123456. Note: 1) Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
Parameters Description 7
Device EUI App EUI Application Port Join Type Unique ID of the device which can also be found on the label. Default App EUI is 24E124C0002A0001. The port used for sending and receiving data, default port is 85. OTAA and ABP mode are available. Application Key Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823. Device Address DevAddr for ABP mode, default is the 5th to 12th digits of SN.
LoRaWAN Frequency Settings: Go to Setting > LoRaWAN Settings of ToolBox App to select supported frequency and select channels to send uplinks. Make sure the channels match the LoRaWAN® gateway. If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas.
3.3 Basic Settings Go to Device > Setting > General Settings of ToolBox App to change the reporting interval, etc. Parameters Device Mode Description Select from Standard Mode, Bin Mode or Parking Lot Mode. Reporting interval of transmitting data to network server. Standard Mode: 10 minutes as default; Reporting Interval Bin mode: 20 minutes as default; Parking Lot Mode: 1080 minutes as default. If the sensor detects the occupancy status change, it will report immediately.
Tilt & Distance Switch Change Password When detecting that the offset angle is greater than 20 degrees, turn off the distance sensor. Change the password for ToolBox App or software to access this device. 3.4 Advanced Settings 3.4.1 Calibration Settings Go to Device > Setting > Calibration Settings to enable calibration. EM400-MUD supports two calibration types. Numerical Calibration: users can define calibration value to correct every distance.
according to collecting interval. If threshold is triggered, it uploads the current data once instantly. Note: threshold setting is only for bin mode and standard mode. Parameters Collecting Interval Threshold Dismiss Report Description Collecting interval to detect distance, this should be smaller than or equal to reporting interval. When the collected value changes from outside the threshold to within the threshold, a threshold release packet will be reported. 3.5 Maintenance 3.5.1 Upgrade 1.
3.5.2 Backup EM400-MUD support configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRaWAN® frequency band. 1. Go to Template page on the App and save current settings as a template. You can also edit the template file. 2. Select one template file which saved in the smartphone and click Write, then attach to another device to write configuration. Note: Slide the template item left to edit or delete the template.
3.5.3 Reset to Factory Default Please select one of following methods to reset device: Via Hardware: Hold on power button (internal) for more than 10s. Via ToolBox App: Go to Device > Maintenance to click Reset, then attach smartphone with NFC area to device to complete reset. 4. Installation 1. Drill two holes on the container cover according to the location of device mounting holes.
2. Put the device under container cover and align the holes in order to perfectly screw the bolts into the holes from the other side of the cover. Besides, the device can also be fixed by two M4 mounting screws and wall plugs. Installation location: In order to provide the best data transmission, please ensure the device is deployed within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles.
When EM400-MUD is in waste bin mode, place the device in the center of waste bin mode and here are some recommended sizes of waste bins: when the height is 88cm, the minimum radius should be 24cm. 5. Device Payload All data are based on following format (HEX): Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3 ... 1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte ... For decoder examples please find files on https://github.com/Milesight-IoT/SensorDecoders. 5.
Channel Type Description 01 75(Battery Level) UINT8, Unit: % 03 67 (Temperature) INT16, Unit: °C 04 82 (Distance) 05 00 (Device Position) INT16, Unit: mm 00: Normal (horizontal offset angle < 20°) 01: Tilt (horizontal offset angle ≥ 20°) Example: 017564 0367f800 04820101 050000 Channel Type 01 75 (Battery) Channel 04 Value Channel Type Value 64 => 100% 03 67 (Temperature) f8 00 => 00 f8 = 248 * 0.1 =24.
Example: 1. Distance Threshold 8482330701 Channel Type Value 84 82 (Distance) Distance: 33 07 =>07 33 = 1843mm = 1.843m Alarm Status: 01= Alarm 2. Temperature Threshold 8367220101 Channel Type Value 83 67 (Temperature) Temperature: 22 01 =>01 22 = 290 * 0.1 = 29°C Alarm Status: 01= Alarm 5.3 Downlink Commands EM400-MUD supports downlink commands to configure the device. Application port is 85 by default.
010-Bin Mode Bit6=0 Bit7: 0 - disable threshold dismiss report 1 - enable threshold dismiss report 70 (Set Height Threshold in 2 Bytes, unit: mm Parking Lot Mode) 77 (Set Installation Height) 2 Bytes, unit: mm Example: 1. Set reporting interval as 20 minutes. ff03b004 Channel Type Value ff 03 (Set Reporting Interval) b0 04 => 04 b0 = 1200s = 20 minutes 2. Reboot the device. ff10ff Channel Type Value ff 10 (Reboot) ff (Reserved) 3. Set the device as standard mode.
Min: c8 00 => 00 c8 = 200 mm = 20 cm Max: 2003 => 03 20 = 800 mm = 80cm 6. Set the height threshold in parking lot mode as 0.03m. ff701e00 Channel Type Value ff 70 (Set Height Threshold in Parking Lot Mode) 1e 00 => 00 1e =30mm =0.03m 7. Set the installation height as 4.5m. ff779411 Channel Type Value ff 77 (Set Installation Height) 94 11 => 11 94 =4500mm =4.