3.3 General Settings
Go to Device > Setting > General Settings of ToolBox App to change the reporting interval, etc.
Parameters
Description
Reporting Interval
The interval of sending battery level and display template option to network
server. Range: 1-1080 mins, default: 1080 min
Buzzer
When buzzer is enabled, it will response when you press the screen button
or the device receives the downlink command to refresh the screen.
Screen Button
When screen button is pressed, the device will uplink an empty packet to
open the reception window to wait for downlink commands. It is suggested
to enable this button if work mode is Class A.
Note: if device does not join the network, press this button to send a join
request packet.
Display Template
Select the display template. DS3604 supports 2 templates at most.
Least Refresh
Interval
The interval to full refresh the screen. Range: 1-90 days, default: 30 days.
Change Password
Change the password for ToolBox App or ToolBox software to write this
device.
3.4 Display Settings
DS3604 provides 2 display templates and supports display content programming according to
user requirements. Besides, users can use default template 1 on dynamic hot desk reservation
and default template 2 on fixed workplace display signage applications.
1. Go to
Device > Setting > Display Settings of ToolBox App to add module directly or click Read
and attach the smartphone with NFC area to the device to get the default display template.