User's Guide

Chapter Three - 24
Managing Power
Battery Maintenance & Storage Recommendations EE
Battery power will decrease gradually in storage. The rate depends on “self-discharge rate”
and the storage environment. Self-discharge rate of rechargeable batteries is approximately
1% per day. High humidity and high temperature accelerate discharge. Very low
temperature may “freeze” the battery chemicals thus decrease the capacity. The following
are guidelines for battery maintenance:
The battery life with system off is approximately 60 days, so it is suggested that the
battery be charged every two months so to avoid over discharging.
The battery should be removed if it will not be used for a long period of time
(approximately one month).
The battery should have 50% charge remaining before it is removed and be stored in
the temperature range of -20°C to 20°C.
The battery without using for more than 2 years may result in battery aging and it is not
recommended to use.
Self-discharge rate is related to storage temperature. The following recommendations
may show how often a battery removed from the device needs to be charged in different
storage temperatures.
- In -20°C ~ 20°C environment, it is recommended to charge the battery every year;
- In -20°C ~ 45°C environment, it is recommended to charge the battery every three
months;
- In -20°C ~ 60°C environment, it is recommended to charge the battery every month.