Owners Manual

3
Front Panel Layout
15
1 2 3 4 5 6 7
8 9 10 11 12 13 14
1 2 3 4 5 6
8 9 10 11 12 13 14
Front Panel Layout
1. GAIN – Selects Input level gain from 20 to 70dB
2. IMPEDANCE SELECTOR – Used to switch in input impedance
from300,600or1200Ohminputload
3. HI PASS Switch – Used to Engage the High Pass Filter
4. FREQUENCY–ControlusedtosettheCutOfrequencyfromthe
High Pass Filter
5. OUTPUT LEVEL – Control knob to adjust output level
6. PEAK METER – ree-segment LED peak meter to show the
absolute clipping point
7. POWER LIGHT – When illuminated indicates the unit is powered
on and ready for operation
8. INST/LINE INPUT – ¼-inch input jack to connect instrument or
line level signal
9. INST/LINE switch -Push switch to selet Line or Instrument input
10. 48V PHANTOM POWER SWITCH - Used to Engage 48 Volt
phantom supply for power condenser microphones or active direct
boxes
11. PHASE Switch – Used to select normal or inverted Phase
12. SMOOTH Switch – Selects normal or Smooth mode
13. METER Switch – Used to assign input or output level to the VU
Meter
14. VU METER – Displays the input or output level
15. POWER Switch - Mains power switch to power the unit on or off