4. Start up
After connecting the temperature sensors (standard: PT-100) and power supply, the controller is switched on automatically.
After displaying a “welcome” text the current hour, minute, channel 1 and channel 2 measurements are displayed
consecutively.
When the display shows “---”, the controller indicates that a measuring element is missing or damaged.
Diodes located at keys indicate current status of the device (e.g. edit or auto start mode). Horizontal lines on the left side of
displayed measured value indicate regulator status: diode on signals that an output is programmed. Key LEDS indicates the
current operating mode. The following modes can be indicated: AUTOSTART, START, INFO and EDIT.
In the STOP mode, after the START mode is completed, the display shows instead of hour and minute.
ATTENTION!
In case of power failure the controller saves in memory its current operating mode and when power is
back, it returns to the same mode (unless time set in cell 48 Setup has passed).
5. Operator panel
1. Clock RTC/Process time
2. AUTOSTART mode key
3. Boiler temperature - Channel 1
4. INFO mode key
5. Bar temperature
6. START mode key
7. Meat-bar temperature Channel 2/ counted pasterisation number