EN 2023.03.21 INDU-50 CONTROLLER USER'S MANUAL v1.95(86)EN www.mikster.
Controller user's manual INDU-50 v1.95(86)EN Table of contents 1. Introduction ....................................................................................................................................................................... 3 2. Elements ............................................................................................................................................................................ 4 3. Assembly ...........................................................
Controller user's manual INDU-50 v1.95(86)EN 1. Introduction Thank you for choosing and purchasing the Industrial Microprocessor Controller INDU-50. We hope that You will find our product to be reliable and easily operated. Please read carefully the User’s manual. This will enable You to obtain the best effects in using the system and to prolong the service life of devices. Microprocessor controller INDU-50 is intended for servicing heat boilers, smoke houses, cooking ovens.
Controller user's manual INDU-50 v1.95(86)EN Elements 2. The UNDU-50 consists od the following elements: 1. 2. 3. 4. 5. 6. 7. 8. 9. |4 Industrial Microprocessor Controller INDU-50 – 1 item, Clamping elements – 4 item, Mask elements – 6 item, Clamping screw – 10 item, CD with Loggisoft LT software, User’s manual, Plug AKZ950x14 – 1 item, Plug AKZ950x12 – 1 item, Plug AKZ950x2 – 1 item, www.mikster.
Controller user's manual INDU-50 v1.95(86)EN 3. Assembly ATTENTION! Silicon washer should be lubricated by technical vaseline. Be aware that the washer should accurately adhere to the assembling surface. ATTENTION! (1) Before connecting, verify the supply voltage on the device label. Depending on the version: 230V AC, 110-230V AC, 24V AC, 24V AC/DC www.mikster.
Controller user's manual INDU-50 v1.95(86)EN 4. Start up After connecting the temperature sensors (standard: PT-100) and power supply, the controller is switched on automatically. After displaying a “welcome” text the current hour, minute, channel 1 and channel 2 measurements are displayed consecutively. When the display shows “---”, the controller indicates that a measuring element is missing or damaged. Diodes located at keys indicate current status of the device (e.g. edit or auto start mode).
Controller user's manual INDU-50 v1.95(86)EN 6. 6.1. Operation description EDIT mode – setpoint changing To get into the setpoint edit mode press the EDIT key. . When the edit mode is activated, the EDIT key flashes . You can change parameters on the display by using the keyboard To confirm or move to the next field, press to exit press . .
Controller user's manual INDU-50 v1.95(86)EN 6.3. AUTOSTART mode Press the key to edit parameters for this mode. AUTOSTART mode can be activated in two ways: 1. 2. At specified time (hour and minute) and daily delay, if any (F47 SETUP – HMD). After counting down a specified time (hours and minutes) (F47 SETUP - HM) Pressing START button during edit mode couses begining of waiting mode for START (AUTOSTART). To quit the AUTOSTART mode, press the key pressing the START key. 6.4. once again.
Controller user's manual INDU-50 v1.95(86)EN 6.5. Service functions accessible for the user Cell no Description UF0 Real time clock setting press for the next parameter UF1 Access code changing to the user’s function Range 0..999 Value 0 – access code off UF2 Information on software version UF3 Keyboard click ON/OFF To get into the user’s setting press and hold down the key and then press and hold down the key . The functions mentioned above are available after the access code is entered.
Controller user's manual INDU-50 v1.95(86)EN 7. Pasterisation Due to frequent application of INDU50 controller as a unit controlling the process of thermal food processing, its properties were widened by the possibility of counting the pasterisation number according to the aritmetric variant of the general method. The following sterilisation coefficients were applied: (z = 4.8K; z = 7.
Controller user's manual INDU-50 v1.95(86)EN Governor diagrams 8. Governor – simple histeresis – heating Type 0* Governor – reversed histeresis – refrigeration Type 1* Tz – temperature setpoint t – time Tz – temperature setpoint t – time Governor – simple histeresis – algorithm of temperature approaching Type 2* Governor PID Type 3* Temperature control can be divided into three zones. In the first zone the output Dout is controlled until Tza temperature is reached.
Controller user's manual INDU-50 v1.95(86)EN Governor relative Type 4 Governor dedicated for jacket temperature control in parboilers. Jacket temperature control is carried out on the basis of the relationship between the preset and the read-out water temperature. ATTENTION! This type of governor is only available on channel 3 (cell setting SF31); controller configuration parameters: SF87,103, SF104, SF105. 9.
Controller user's manual INDU-50 v1.95(86)EN 10. Controller setup To get into the SETUP menu, press and hold down the key and then press the code (if included in Setup cell SF 74) you can change the controller parameters. No. Default value Range SF0 1 0..128 SF1 0 0..4 Baud rate 0-9600, 1-19200, 2-38400, 3-57600, 4-115200 SF2 1 0..12 Channel 1 measuring input type Standard version: 0 – PT-500 1 – PT-100 2 – PT1000 key.
Controller user's manual INDU-50 v1.95(86)EN No. Default value Range Description SF16 200°C -99,0..999°C Value corresponding to 20 mA for channel 3 4..20 mA input SF17 0,0°C -20,0..20°C Temperature readout adjustment for channel 1 SF18 0,0°C -20,0..20,0°C Temperature readout adjustment for channel 2 SF19 0,0°C -20,0..
Controller user's manual INDU-50 v1.95(86)EN www.mikster.eu No. Default value Range Description SF39 20°C 0..200°C Regulator activation temperature (Tza) for channel 1 For “setpoint ramping” algorithm SF40 20°C 0..200°C Regulator activation temperature (Tza) for channel 2 For “setpoint ramping” algorithm SF41 20°C 0..200°C Regulator activation temperature (Tza) for channel 3 For “setpoint ramping” algorithm SF42 1 0..
Controller user's manual INDU-50 v1.95(86)EN No.
Controller user's manual INDU-50 v1.95(86)EN www.mikster.eu SF80 0 0..5 SF81 52°C 0..100°C SF82 SF83 SF84 0 0..2 1 0 ..2 2 0..2 SF85 SF86 SF87 0 0 0 -50..100°C -50..100°C -50..100°C SF88 0 0..4 Process triggering method 0 – START key 1 – Input 1 2 – Input 2 3 – Input 1 or 2 4 – Input 1 or 2 SF89 0 0..1 Measurement recording frequency unit (applies to SF49): 0 – min 1 – sec SF90 0 0..
Controller user's manual INDU-50 v1.95(86)EN 11. 12. Relays REL 1 Relay output of governor 1 REL 2 Relay output of governor 2 REL 3 Relay output of governor 3 REL 4 Switched on in START mode REL 5 Alarm Example of application Figure 1 Pic. 1. this example is given for informative purpose only and should not be considered in part or in whole as a system design | 18 www.mikster.
Controller user's manual INDU-50 v1.95(86)EN 13. Cycle end conditions Nr www.mikster.
Controller user's manual INDU-50 v1.95(86)EN 14. | 20 The most frequently asked questions (FAQ) 1. What to do when the governor does not switch on? Check the power supply of the governor. 2. The governor does not record the data after the end of the process. Check the setting of the SF46 cell. If continuous recording is required, which means recording regardless of the operation mode, write 0. 3.
Controller user's manual INDU-50 v1.95(86)EN 15. www.mikster.eu Technical data Power supply: 24V AC/DC Imax.140mA 110/230VAC Imax.
Controller user's manual INDU-50 v1.95(86)EN 16. | 22 Dimensions: external 134x134x65mm (W x H x D) mounting 90x90mm (W x H) Fixing: screwed 4 mounting holes (front) or 4 mounting clips (rear) Weight: 500 g (net) IP rating: 65 (front) 20 (rear) Operating conditions: Temperature: 0°C ÷ 55°C Humidity: 5%RH ÷ 85%RH EC compliance: 2014/30/UE ROHS 2011/65/UE 2014/35/UE PN-EN IEC 61000-6-2:2019 PN-EN 61000-4-4:2013-05 PN-EN 61000-4-2:2011 PN-EN 61000-4-11:2007 PN-EN 61131-2:2008 Features www.
Controller user's manual INDU-50 v1.95(86)EN *from the front IP 65 **the front - the resistance to strong cleaning agents used in the food industry 17.
Controller user's manual INDU-50 v1.