Datasheet
Programming PIC Microcontrollers in BASIC - mikroElektronika
Prototype
sub procedure SPI_Init_Advanced(dim Master as byte, dim Data_Sample as
byte, dim Clock_Idle as byte, dim Low_To_High as byte)
Description For advanced settings, configure and initialize SPI using the procedure SPI_Init_Advanced.
Allowed values of parameters:
<Master> determines the work mode for SPI:
● Master_OSC_div4 : Master clock=Fosc/4
● Master_OSC_div16 : Master clock=Fosc/16
● Master_OSC_div64 : Master clock=Fosc/64
● Master_TMR2 : Master clock source TMR2
● Slave_SS_ENABLE : Master Slave select enabled
● Slave_SS_DIS : Master Slave select disabled
<Data_Sample> determines when data is sampled:
● Data_SAMPLE_MIDDLE : input data sampled in middle of interval
● Data_SAMPLE_END : input data sampled at the end of interval
<Clock_Idle> determines idle state for clock:
● CLK_Idle_HIGH : clock idle HIGH
● CLK_Idle_LOW : clock idle LOW
http://www.mikroelektronika.co.yu/english/product/books/picbasicbook/05.htm (95 sur 112)05/11/2004 02:20:55