Note: Manchester receive routines are blocking calls (Man_Receive_Config, Man_Receive_Init, Man_Receive).
This means that PIC will wait until the task is performed (e.g. byte is received, synchronization achieved, etc).
Note: Routines for receiving are limited to a baud rate scope from 340 ~ 560 bps.
5.2.12.1 Man_Receive_Init – Initialization with default pin
Prototype
sub procedure Man_Receive_Init(dim byref Port as byte)
Description Procedure works same as Man_Receive_Config, but with default pin setting (pin 6).
Example
Man_Receive_Init(PORTD)