User manual

Table Of Contents
mikroC PRO for PIC32
MikroElektronika
583
TP_Get_Calibration_Consts
Prototype
void TP_Get_Calibration_Consts(unsigned int *x_min, unsigned int *x_max,
unsigned int *y_min, unsigned int *y_max);
Description Gets calibration constants after calibration is done and stores them in x_min, x_max, y_min and
y_max parameters.
Parameters - x_min: x coordinate of the bottom left corner of the working area.
- x_max: x coordinate of the upper right corner of the working area.
- y_min: y coordinate of the bottom left corner of the working area.
- y_max: y coordinate of the upper right corner of the working area.
Returns Nothing.
Requires Nothing.
Example
TP_Get_Calibration_Consts(&x_min, &y_min, &x_max, &y_max); // Get
calibration constants
Notes None.
TP_Set_Calibration_Consts
Prototype
void TP_Set_Calibration_Consts(unsigned int x_min, unsigned int x_max,
unsigned int y_min, unsigned int y_max);
Description Sets calibration constants.
Parameters - x_min: x coordinate of the bottom left corner of the working area.
- x_max: x coordinate of the upper right corner of the working area.
- y_min: y coordinate of the bottom left corner of the working area.
- y_max: y coordinate of the upper right corner of the working area.
Returns Nothing.
Requires Nothing.
Example
TP_Set_Calibration_Consts(148, 3590, 519, 3370); // Set calibration
constants
Notes None.