TP_TFT_Get_Calibration_Consts
Prototype
sub procedure TP_TFT_Get_Calibration_Consts(dim byref x_min as word, dim
byref x_max as word, dim byref y_min as word, dim byref y_max as word)
Description Gets calibration constants after calibration is done and stores them in x_min, x_max, y_min and
y_max parameters.
Parameters - x_min: x coordinate of the bottom left corner of the working area.
- x_max: x coordinate of the upper right corner of the working area.
- y_min: y coordinate of the bottom left corner of the working area.
- y_max: y coordinate of the upper right corner of the working area.
Returns Nothing.
Requires Nothing.
Example
TP_TFT_Get_Calibration_Consts(@x_min, @y_min, @x_max, @y_max) Get
calibration constants
Notes None.
TP_TFT_Set_Calibration_Consts
Prototype
sub procedure TP_TFT_Set_Calibration_Consts(dim x_min as word, dim x_max as
word, dim y_min as word, dim y_max as word)
Description Sets calibration constants.
Parameters - x_min: x coordinate of the bottom left corner of the working area.
- x_max: x coordinate of the upper right corner of the working area.
- y_min: y coordinate of the bottom left corner of the working area.
- y_max: y coordinate of the upper right corner of the working area.
Returns Nothing.
Requires Nothing.
Example
TP_TFT_Set_Calibration_Consts(148, 3590, 519, 3370) Set calibration
constants
Notes None.