User manual
560
mikoBasic PRO for dsPIC30/33 and PIC24
MikroElektronika
SPI_T6963C_grFill
SPI_T6963C_txtFill
Prototype
sub procedure SPI_T6963C_grFill(dim v as word)
Description Fill current graphic panel with appropriate value (0 to clear).
Parameters - v: value to ll graphic panel with.
Returns Nothing.
Requires Toshiba Glcd module needs to be initialized. See SPI_T6963C_Cong routine.
Example
‘ clear current graphic panel
SPI_T6963C_grFill(0)
Notes None.
Prototype
sub procedure SPI_T6963C_txtFill(dim v as word)
Description Fill current text panel with appropriate value (0 to clear).
Parameters - v: this value increased by 32 will be used to ll text panel.
Returns Nothing.
Requires Toshiba Glcd module needs to be initialized. See SPI_T6963C_Cong routine.
Example
‘ clear current text panel
SPI_T6963C_txtFill(0)
Notes None.
SPI_T6963C_cursor_height
Prototype
sub procedure SPI_T6963C_cursor_height(dim n as byte)
Description Set cursor size.
Parameters - n: cursor height. Valid values: 0..7.
Returns Nothing.
Requires Toshiba Glcd module needs to be initialized. See SPI_T6963C_Cong routine.
Example
SPI_T6963C_cursor_height(7)
Notes None.