Datasheet
Library Routines
- Man_Receive_Init
- Man_Receive
- Man_Send_Init
- Man_Send
- Man_Synchro
- Man_Break
The following routines are for the internal use by compiler only:
- Manchester_0
- Manchester_1
- Manchester_Out
Man_Receive_Init
248
MIKROELEKTRONIKA - SOFTWARE AND HARDWARE SOLUTIONS FOR EMBEDDED WORLD
Libraries
mikroBasic PRO for AVR
CHAPTER 6
Prototype
sub function Man_Receive_Init()as word
Returns
- 0 - if initialization and synchronization were successful.
-
1 - upon unsuccessful synchronization.
Description
The function configures Receiver pin and performs synchronization procedure in
order to retrieve baud rate out of the incoming signal.
Note: In case of multiple persistent errors on reception, the user should call this
routine once again or Man_Synchro routine to enable synchronization.
Requires
Global variables :
- MANRXPIN : Receive line
-
MANRXPIN_Direction : Direction of the receive pin
must be defined before using this function.
Example
' Initialize Receiver
dim MANRXPIN as sbit at PINB.B0
dim MANRXPIN_Direction as sbit at DDRB.B0
...
Man_Receive_Init()