Datasheet
Cf_Read_Sector
Cf_Write_Sector
196
MIKROELEKTRONIKA - SOFTWARE AND HARDWARE SOLUTIONS FOR EMBEDDED WORLD
Libraries
mikroBasic PRO for AVR
CHAPTER 6
Prototype
sub procedure Cf_Read_Sector(dim sector_number as longword, dim
byref buffer as byte[512])
Returns Nothing.
Description
Reads one sector (512 bytes). Read data is stored into buffer provided by the
buffer parameter.
Parameters :
-
sector_number: sector to be read.
-
buffer: data buffer of at least 512 bytes in length.
Requires
The corresponding MCU ports must be appropriately initialized for CF card. See
Cf_Init.
Example
' read sector 22
dim data as array[512] of byte
...
Cf_Read_Sector(22, data)
Prototype
sub procedure Cf_Write_Sector(dim sector_number as longword, dim
byref buffer as byte[512])
Returns Nothing.
Description
Writes 512 bytes of data provided by the buffer parameter to one CF sector.
Parameters :
-
sector_number: sector to be written to.
-
buffer: data buffer of 512 bytes in length.
Requires
The corresponding MCU ports must be appropriately initialized for CF card. See
Cf_Init.
Example
' write to sector 22
dim data as array[512] of byte
...
Cf_Write_Sector(22, data)