© 2008 Microchip Technology Inc. DS39646C-page 389
PIC18F8722 FAMILY
Module Differential Currents (ΔIWDT, ΔIBOR, ΔILVD, ΔIOSCB, ΔIAD)
D022
(ΔI
WDT)
Watchdog Timer 1.5 2.2 μA-40°C
V
DD = 2.0V
1.6 2.2 μA +25°C
1.7 2.3 μA +85°C
2.3 3.5 μA-40°C
VDD = 3.0V
2.4 3.5 μA +25°C
3.4 3.5 μA +85°C
4.8 7.5 μA-40°C
V
DD = 5.0V
6.0 7.5 μA +25°C
6.1 7.8 μA +85°C
810μA +125°C
D022A
(ΔI
BOR)
Brown-out Reset
(4)
4.2 50 μA -40°C to +85°C VDD = 3.0V
48 55 μA -40°C to +85°C
V
DD = 5.0V
66 55 μA -40°C to +125°C
02.4μA -40°C to +85°C Sleep mode,
BOREN<1:0> =
10
06.0μA -40°C to +125°C
D022B
(ΔI
LVD)
High/Low-Voltage Detect
(4)
2.7 38 μA -40°C to +85°C VDD = 2.0V
30 40 μA -40°C to +85°C VDD = 3.0V
35 45 μA -40°C to +85°C
V
DD = 5.0V
36 45 μA -40°C to +125°C
D025
(ΔI
OSCB)
Timer1 Oscillator 4.5 9 μA-40°C
(3)
VDD = 2.0V 32 kHz on Timer1
.9 1.7 μA-10°C
.9 2.2 μA +25°C
.9 2.2 μA +85°C
4.8 10 μA-40°C
(3)
VDD = 3.0V 32 kHz on Timer1
11.8μA-10°C
12.3μA +25°C
12.3μA +85°C
611μA-40°C
(3)
VDD = 5.0V 32 kHz on Timer1
1.6 6 μA-10°C
1.6 6 μA +25°C
1.6 6 μA +85°C
28.2 DC Characteristics: Power-Down and Supply Current
PIC18F6X27/6X22/8X27/8X22 (Industrial, Extended)
PIC18LF6X27/6X22/8X27/8X22 (Industrial) (Continued)
PIC18LF6X27/6X22/8X27/8X22
(Industrial)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
PIC18F6X27/6X22/8X27/8X22
(Industrial, Extended)
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C T
A +85°C for industrial
-40°C T
A +125°C for extended
Param
No.
Device Typ Max Units Conditions
Legend: Shading of rows is to assist in readability of the table.
Note 1: The power-down current in Sleep mode does not depend on the oscillator type. Power-down current is measured with
the part in Sleep mode, with all I/O pins in high-impedance state and tied to V
DD or VSS and all features that add delta
current disabled (such as WDT, Timer1 Oscillator, BOR, etc.).
2: The supply current is mainly a function of operating voltage, frequency and mode. Other factors, such as I/O pin loading
and switching rate, oscillator type and circuit, internal code execution pattern and temperature, also have an impact on
the current consumption.
The test conditions for all I
DD measurements in active operation mode are:
OSC1 = external square wave, from rail-to-rail; all I/O pins tri-stated, pulled to V
DD OR VSS;
MCLR
= VDD; WDT enabled/disabled as specified.
3: When operation below -10°C is expected, use T1OSC High-Power mode, where LPT1OSC (CONFIG3H<2>) = 0. When
operation will always be above -10°C, then the low-power Timer1 oscillator may be selected.
4: BOR and HLVD enable internal band gap reference. With both modules enabled, current consumption will be less than
the sum of both specifications.